Hydrotechnik overview of HT-PD PR150 Pressure sensor
|
HT-PD PR150 Pressure sensor |
Hydrotechnik in china |
HT-PD PR150 Pressure sensor data download |
HT-PD PR150 Pressure sensor
Product range pressure sensors type HT-PD PR150
The latest thinfilm WSG pressure sensor type HT-PD PR150 from Hydrotechnik was developed in order to measure pressures and pressure peaks within an extended temperature band. Its strongest attributes lie in the following areas:
• Reliability
• Repeatability
• Temperature stability
• Robust industrial design
• Media compatibility
• Resistance to thermal shocks and vibrations
|
Hydrotechnik Technical data of HT-PD PR150 Pressure sensor
HT-PD PR150 Technical data |
Overload range |
1.5 x nominal pressure |
Burst pressure |
3 x nominal pressure |
Signal type |
Two wire analog (4 ... 20 mA), three wire analog (0 ... 10 VDC) |
Supply voltage Ub |
... at 4 ... 20 mA |
10...30VDC |
... at 0 ... 10 VDC |
12...32VDC |
Current consumption |
6.5mA |
Overvoltage protection |
32VDC |
Error limit (of fi nal value) |
comprises the infl uences non-linearity, hysterese, repeatability, zero-point- and span error |
... at +22 °C (room temperature) |
±0.5% |
... at -15 ... +85°C |
±1% |
... at +85 ... +100°C |
±2.5% |
... at -40 ... -15°C |
±2.5% |
Compensation temperature range |
-40...+100 |
Non-linearity |
< ± 0.4 % of final value |
Reproducability |
< ± 0.1 % of final value |
Hysterese |
< ± 0.1 % of final value |
Long-term stability |
< ± 0.1 % of final value/year |
Response time |
< = 1 ms (10 ... 90 %) |
Frequency range |
< = 1 kHz |
Isolation resistance |
min. 100 MOhm |
Total resistance |
RG = (Ub -10 V) / 20 mA (at output signal 4 ... 20 mA) |
Load resistance |
RL = > 5 kOhm (at output signal 0 ... 10 VDC) |
Number of load cycles |
> 1 x 107 |
Medium temperature |
-40...+125 |
Environmental temperature |
-40 ... +105 °C (short term +125 °C) |
Storage temperature |
-40...+125 |
EMV test |
EN 50081-2, EN 50082-2 |
Vibrational stability |
5 mm 10 ... 32 Hz, 20 g 32 ... 500 Hz, DIN EN 60068-2-6 |
Shock stability |
50 g (11 ms half-sine) |
Electrical measuring connector |
4 pole device connector,DIN EN 175301-803, type C, Pg7 |
Mechanical connection thread |
ISO228-G1/4A |
Sealing material |
profi le seal ring acc. to DIN 3869, FKM |
Protection type (EN 60529 / IEC 529) |
IP 65 (with connecting cable Ø 4,5 ... 6 mm) |
Casing material |
non-corrosive high-grade steel |
Membrane material |
non-corrosive high-grade steel |
Tightening torque |
40 Nm (± 5 Nm) |
Weight |
~ 97 g |
Hydrotechnik HT-PD PR150 Dimensions
Hydrotechnik HT-PD PR150 Electrical connector
Pin assignment |
4 ... 20 mA (two wires) |
0 ... 10 V (three wires) |
|
1 + Ub / signal + |
1 + Ub |
2 – Ub / signal – |
2 – Ub / signal – / GND |
3 free |
3 Signal + |
Hydrotechnik pressure sensors HT-PD PR150 4...20mA output
Measuring range(MPa) |
Measuring range(Bar) |
4...20mA |
-0.1...0MPa |
-1...0bar |
3403-30-D5.37 |
-0.1...0.6MPa |
-1...6bar |
3403-32-D5.37 |
-0.1...1MPa |
-1...10bar |
3403-54-D5.37 |
0...0.6MPa |
0...6bar |
3403-28-D5.37 |
0...1.0MPa |
0...10bar |
3403-26-D5.37 |
0...1.6MPa |
0...16bar |
3403-41-D5.37 |
0...4.0MPa |
0...40bar |
3403-31-D5.37 |
0...6.0MPa |
0...60bar |
3403-21-D5.37 |
0...10.0MPa |
0...100bar |
3403-16-D5.37 |
0...20.0MPa |
0...200bar |
3403-10-D5.37 |
0...25.0MPa |
0...250bar |
3403-17-D5.37 |
0...40.0MPa |
0...400bar |
3403-15-D5.37 |
0...60.0MPa |
0...600bar |
3403-18-D5.37 |
0...100.0MPa |
0...1000bar |
3403-29-D5.37 |
Hydrotechnik pressure sensors HT-PD PR150 0...10VDC output
Measuring range(MPa) |
Measuring range(Bar) |
0...10VDC |
-0.01...0MPa |
-0.1...0bar |
3403-60-D5.39 |
-0.1...0.2MPa |
-1...2bar |
3403-68-D5.39 |
-0.1...0.6MPa |
-1...6bar |
3403-32-D5.39 |
0...0.02MPa |
0...0.2bar |
3403-61-D5.39 |
0...0.2MPa |
0...2bar |
3403-25-D5.39 |
0...0.6MPa |
0...6bar |
3403-28-D5.39 |
0...1.0MPa |
0...10bar |
3403-26-D5.39 |
0...2.0MPa |
0...20bar |
3403-27-D5.39 |
0...2.5MPa |
0...25bar |
3403-40-D5.39 |
0...4.0MPa |
0...40bar |
3403-31-D5.39 |
0...6.0MPa |
0...60bar |
3403-21-D5.39 |
0...10.0MPa |
0...100bar |
3403-16-D5.39 |
0...20.0MPa |
0...200bar |
3403-10-D5.39 |
0...25.0MPa |
0...250bar |
3403-17-D5.39 |
0...40.0MPa |
0...400bar |
3403-15-D5.39 |
0...60.0MPa |
0...600bar |
3403-18-D5.39 |
0...100.0MPa |
0...1000bar |
3403-29-D5.39 |
Hydrotechnik's HT-PD PR150 related products